H3c-technologies H3C SecPath L1000-A Load Balancer Instrukcja Użytkownika Strona 48

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 47
40
Hardware management and maintenance
This chapter describes how to display running information for the L1000-A, verify and diagnose
transceiver modules, troubleshoot system exceptions, and reboot the L1000-A.
NOTE:
The output depends on your software version.
Displaying detailed information about the L1000-A
Use the display device verbose command to display detailed information about the L1000-A and
interface modules.
<H3C> display device verbose
Status :OK
Type :RPU
Hardware :B
Driver :1.0
CPLD :3.0
SubCard Num :3
CFCard Num :0
Usb Num :1
The Fixed SubCard0 on Board0
Status :Normal
Type :Fixed Subcard
Hardware :B
Driver :1.0
CPLD :3.0
The SubCard1 on Board0:
Status :Absent
The SubCard2 on Board0:
Status :Absent
Displaying software and hardware version
information
Use the display version command to display software and hardware version information for the
L1000-A.
<H3C> display version
H3C Comware Platform Software
Przeglądanie stron 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 83 84

Komentarze do niniejszej Instrukcji

Brak uwag