H3c-technologies H3C SecPath F5000-S Firewall Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Bezpieczeństwo H3c-technologies H3C SecPath F5000-S Firewall. H3C Technologies H3C SecPath F5000-S Firewall User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 4
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
M
o
u
n
t
i
n
g
t
h
e
F
i
r
e
w
a
l
l
t
o
a
R
a
c
k
3
P
l
a
c
e
t
h
e
f
i
r
e
w
a
l
l
i
n
t
h
e
r
a
c
k
a
n
d
s
e
c
u
r
e
t
h
e
f
i
r
e
w
a
l
l
t
o
t
h
e
r
a
c
k
p
o
s
t
s
w
i
t
h
M
6
s
c
r
e
w
s
.
M
6
A
t
t
a
c
h
t
h
e
m
o
u
n
t
i
n
g
b
r
a
c
k
e
t
s
t
o
t
h
e
f
i
r
e
w
a
l
l
.
t
h
e
m
a
r
k
e
d
p
o
s
i
t
i
o
n
s
o
n
t
h
e
r
a
c
k
p
o
s
t
.
A
c
a
g
e
n
u
t
i
s
i
n
s
t
a
l
l
e
d
t
o
t
h
e
r
a
c
k
p
o
s
t
.
M
a
r
k
t
h
e
p
o
s
i
t
i
o
n
s
o
f
t
h
e
c
a
g
e
n
u
t
s
o
n
t
h
e
r
a
c
k
p
o
s
t
b
y
u
s
i
n
g
a
m
o
u
n
t
i
n
g
b
r
a
c
k
e
t
.
I
n
s
t
a
l
l
t
h
e
c
a
g
e
n
u
t
s
t
o
4
T
o
a
v
o
i
d
b
o
d
i
l
y
i
n
j
u
r
y
a
n
d
f
i
r
e
w
a
l
l
d
a
m
a
g
e
,
u
s
e
a
t
l
e
a
s
t
t
w
o
p
e
o
p
l
e
t
o
m
o
u
n
t
t
h
e
f
i
r
e
w
a
l
l
t
o
t
h
e
r
a
c
k
b
e
c
a
u
s
e
t
h
e
f
i
r
e
w
a
l
l
i
s
h
e
a
v
y
.
Mounting bracket
(required)
挂耳(标配)
Rubber pads
(required)
胶垫贴(标配)
Tool List 工具参考
Introduction to Installation Accessories安装附件介绍
Grounding cable
(required)
地线(标配)
Cage nut
(user supplied)
浮动螺母(用户自备)
M6 screw
(user supplied)
M6 螺钉(用户自备)
Removable cable tie
(user supplied)
可拆卸式扎带(用户自备)
Bail latch (required)
电源卡钩(标配)
Phillips
screwdriver
十字螺丝刀
Needle-nose
pliers
尖嘴钳
Wire-stripping
pliers
剥线钳
Diagonal pliers
斜口钳
ESD-preventive wrist
strap
防静电腕带
Marker
记号笔
M4 countersunk-head
screw (required)
M4沉头螺钉(标配)
2
1
Wear an ESD-preventive wrist strap, and make sure the wrist strap makes
good skin contact and is well grounded.
操作者需佩戴防静电腕带,确保防静电腕带与皮肤良好接触,并确认防静电
腕带已经良好接地。
The installation tools are not provided with the firewall. Prepare them
yourself.
防火墙不随机提供安装工具,请用户根据实际安装需求自备安装工具。
Flat-blade
screwdriver
一字螺丝刀
Wire crimper
压线钳
Airflow of the Firewall 防火墙的风向设计
The firewall adopts left-to-right air aisles.
设备采用左进右出的风道设
Make sure the air inlet and outlet vents are not blocked and the installation
site has a good ventilation system.
请确保设备的进、出风孔不被遮挡,并将设备安装在具有良好通风散热系
统的环境中。
Mounting the Firewall to a Workbench 安装防火墙到工作台
Make sure the workbench is sturdy and well grounded.
Avoid placing heavy objects on the firewall.
保证工作台的平稳与良好接地,并且不要在设备上放置重物。
Attach the rubber pads to the four
round holes in the chassis bottom.
Place the firewall with upside up on
the workbench. 粘贴胶垫到设备底
部,将带胶垫贴的设备平放到工作
台上
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1 - 保证工作台的平稳与良好接地,并且不要在设备上放置重物。

Mounting the Firewall to a Rack 安装防火墙到机柜3Place the firewall in the rack and secure the firewall to the rack posts with M6 screws.将设备安装进机柜中,用M6螺钉将设备固

Strona 2

Connecting the Grounding Cable 连接保护地线 Installing an SPU 安装业务板1. Remove the filler panel from the SPU slot.拆卸业务板槽位假面板2. Insert the SPU into the slo

Strona 3 - 操作 命令 说明

St ep Co m m an d Rem ark s (1) Enter system view. syst em- view Available in user view. (2) Set the device name. sysname sysname By default,

Strona 4

1234567Assign the PC an IP address 192.168.0.0/24 (except 192.168.0.1), connect the PC toGigabitEthernet 0/0, and launch a Web browser. On the Web l

Powiązane modele: H3C SecPath F5000-C Firewall

Komentarze do niniejszej Instrukcji

Brak uwag